Building fire safety
Fire door won't close? Hong Kong repair and replacement guide
Does your fire or smoke-stop door fail to close, drag on the floor or have damaged hinges or glazing? Find out what to record, when to arrange a check and what a repair or replacement quotation should cover.
Quick answers
Will replacing the closer fix a smoke-stop door that does not shut?
Not necessarily. Hinges, the frame, a distorted leaf or other fittings can also affect closing. Arrange an assessment of the cause and suitable parts before repair; do not trim the door, remove fittings or use a wedge as a workaround.
Legal information
Requirements vary by premises. Confirm the work with the responsible professional using the premises use, approved plans, licence conditions and any written directions.
Start with the door's location and purpose
Fire doors form part of a building's fire separation. Closed smoke-stop doors between corridors and stairs help limit smoke and fire spreading into escape routes. For inspection or replacement, check the requirements for the door's location, use and approved design.
For a quotation, identify the floor and whether this is a stair door, flat entrance or another location. Share photos and any approved plans, fire safety direction or door schedule with the building professional reviewing the requirement.
Four problems that need a check
Look for doors held open by wedges or stored items, failure to close, damaged hinges or closers, and damaged leaves or glazing. The FSD checklist identifies missing, defective and improperly closed smoke-stop doors as deficiencies.
Record the date, floor, door location and photos, then ask management to arrange inspection and repairs. Report doors that drag, slam or are difficult to use so the cause can be checked. Do not disconnect the closer or prop the door open.
Keep smoke-stop doors closed and escape doors usable
FSD advises residents to keep smoke-stop doors closed and escape routes clear. Do not add a padlock, bolt or other obstruction as a way to keep an escape door shut.
Before adding access control, ask the responsible building professional to review escape operation, power-failure behaviour and applicable requirements. Have existing powered equipment checked against its design; do not disconnect or rewire it yourself.
Confirm the specification and documents before replacement
Confirm the fire-resistance rating and configuration required for the door's location and approved design. BD guidance calls for a supplier's statement and test or assessment reports demonstrating the required performance. Ask which documents will be provided with the quotation.
Ask the quotation to identify the leaf, frame, glazing, hinges, closer and associated fittings, and explain how the documents apply to the proposed installation. Have changes to glazing, openings, frames or ventilation grilles assessed before work is authorised.
Keep a repair and handover record for each door
BD advises owners or managers to engage an Authorized Person when fire-resisting construction is defective or has been altered without authorisation, including assessment and any necessary approval process. Confirm the appropriate professionals and contractor before arranging the work.
File before-and-after photos, completed work, operation checks, product documents and outstanding items under the floor and door reference. If a fire safety direction applies, confirm who will submit each document and follow up on the department's response.
Practical checklist
- Record the floor, location and door reference with photos
- Report closing failures, damage or obstructed escape operation
- Find available plans, door schedules and fire safety directions
- Check the proposed configuration against the test or assessment reports
- Keep work records, operation checks and outstanding actions
Discuss fire-door and building fire-safety improvements
Start with the address, door location and problem. Share photos, directions or plans if available; other records can follow as needed. We will review the situation, then confirm survey arrangements and which professionals need to be involved.
- Identify defects, locations and the proposed improvement scope
- Coordinate requirement checks with the appropriate building professionals
- Set out the quotation, access arrangements and handover documents
Official sources
The official documents below provide the full requirements and any updates.
Related reading
Hong Kong fire escape routes: obstructions and escape plans
Check corridor obstructions, smoke-stop doors and escape plans, and understand why route width must be checked against the building's approved layout.
Read articlePreparing fire safety improvement works for inspection and handover
After improvement work is completed, arrange testing, document submission and the authority's inspection. Find out what records to prepare, who needs to attend and what to collect at handover.
Read articleA monthly building fire-safety checklist
Use this checklist to review escape routes, fire doors and visible equipment condition each month. Record problems, assign follow-up and keep track of outstanding repairs.
Read articleRELATED SERVICE
Send the direction for an initial review
Explore the service, or email or call us to ask about your premises.
Discuss the work your premises need
Share the premises, proposed scope and timing. For tender enquiries, include the brief and submission deadline. Available drawings and recent reports help us review the work; you can contact us before everything is ready.
Project and tender enquiries